Limits of the main error of measurement | ±0,05; ±0,065; ±0,075; ±0,1; ±0,15, ±0,2; ±0,25; ±0,5; ±1% |
Top limits of measurement | min: Vacuum of -0.125 kPa; Excessive pressure is 0.125 kPa. max: Vacuum of -100 kPa; Excessive pressure is 2.4 MPa. |
Types of explosion protection | Explosion-proof with the type of protection “explosion-proof barrier “d”; Explosion-proof with the type of protection “intrinsically safe electrical circuit” with the level of protection “ia”; Explosion-proof with 2 types of protection: “explosion-proof barrier “d” and “ intrinsically safe electrical circuit” with the level of protection “ia”. |
Output signal of a direct current | 4-20 ma; 20-4 ma 4-20 ma extraction of a root; 0-5 ma (external converter). |
Output digital signal | HART; Modbus RTU (RS-485). |
Heat moisture protection | IP67 |
Supply voltage | from 14 to 42B (Nom. 24B) |
Material of a dividing membrane | Alloy 36НХТЮ; |
Materials of a measuring membrane | Titan of BT9 |
Indication | LED digital indicator. The indicator turns on 360 °C at a slow pace 90 °. Maintains working capacity at low ambient temperatures to -60 °C |
Range of operating ambient temperatures | -60…80 °С |
Temperature range of the measured environment on a sensor entrance | -60 … 80 °C (Not for long 120 °C) |
Loading resistance | Not less than 250 Ohms |
Average time of an operating time | 220 000 h |
Weight unpacked | from 1 to 11 kg |
Middle service life | 20 years |
Intertesting interval | 5 years |
Warranty period | 5 years |